Skip to content

Oxygen and Carbon Dioxide Analyzer

$3,333.00

Description

OXYGEN AND CARBON DIOXIDE ANALYZER

PORTABLE OR BENCHTOP - the Quantek Model is either a benchtop or portable oxygen and carbon dioxide headspace analyzer-primarily used for gas flushed coffee packages. Achieves accurate oxygen and carbon dioxide measurements in 20-25 seconds. This headspace analyzer contains an internal pump to draw in sample from your package and display O2 and CO2 concentration results in 30 seconds. The
expected oxygen sensor life is typically 5 years, unlike other analyzers
with a sensor that last 1-2 years, reducing total cost of ownership,
and analyzer downtime.

SPECIFICATIONS

Technical Specifications Oxygen Channel

Oxygen Sensor Type: Proprietary Electrochemical
Expected Lifetime: 4-5 years
Oxygen Range: 0 to 100%
Oxygen Sensitivity: 0.1% O2
Oxygen Minimum Detection Limit: 0.1% O2
Oxygen Calibration Controls: SPAN adjustment, zero adjustment
O2 Calibration Frequency: Weekly; set with room air set to 20.9% O2.
O2 Resolution: 0.1% O2 (optional .01%)

Technical Specifications Carbon Dioxide Channel

Carbon Dioxide Sensor Type: Solid-state Infrared
Expected Lifetime: Theoretically unlimited
Measurement Ranges: 0-20% or 0-100%
Accuracy (for 0-100% range): 1% of reading, or 0.2% CO2 (whichever is greater)
Accuracy (for 0-20% range): 1% of reading or 0.1% CO2 (whichever is greater)
CO2 Minimum Detection Limit: 0.1% (0-100% range)
CO2 Minimum Detection Limit: 0.01% (0-0-20% range)
CO2 Calibration Controls: Potentiometer SPAN adjustment for CO2.
CO2 Calibration Frequency: Every 18 months; calibration gas recommended.

Technical Specifications - All

Sample Pump - Miniature diaphragm type with ~5cc/sec flow
Pump Timing 2-12 second adjustable pump time, potentiometer on back of analyzer
Sampling Port - Double reinforced sample probe (~12in. length)
Exhaust port Vents to air
Size - Bench Top: 9.8W x 4H x 10L in. (249 x 102 x 254 mm)Portable: 8W x 4H x 1.8L in. (200 x 100 x 40 mm)
Weight - Bench Top: 9.8 lb. (4.4 Kg) | Portable: 1 lb. (450 grms)
Warranty - 2 years, parts and labor
Standards - CE, RoHS,
Origin of Goods - Our products are manufactured in the U.S.A.

Included in Kit

Built-in pump, sample probe.
Starter pack of 200 foam septas
2 needles
2 particulate filters
2 moisture blocking filters
Power supply / charger (for analyzers with optional internal battery) - (International compatible 100-240V)

OPTIONAL ACCESSORIES:

For Can Type Testing - a different probe is needed.  Please contact us for pricing.

Other Accessories Available including long-term supplies, bulk items, replacement parts, and particulate sampling filters - please contact us for the information and the pricing.

EASY SAMPLING & ANALYSIS

The Model 902D analyzer sample probe is tipped with a particulate filter and Luer fit syringe needle with side-port holes to prevent plugging. When the pump is activated, sample is drawn through the probe and tubing and then to the oxygen sensor.

The pump is electronically timed to draw in the precise amount of sample required for the analysis, and then turns itself off after the pre-set sampling time (5 to 10 seconds). The O2 and CO2 concentration is read on the display within 20-25 seconds.

ABOUT THE SENSORS

The solid-state infrared CO2 sensor has no moving parts, a compact optical cell, and microprocessor-based calibration factors using a 6th order polynomial equation and 32-bit processor to linearize the full range measurement up to 100%.

Both sensors are unaffected by high levels of background gases such as nitrogen. The expected life of the CO2 sensor is theoretically unlimited, as it contains no moving parts.

The expected electrochemical O2 sensor life is typically 5 years, unlike
other analyzers with an electrochemical sensor that lasts 1-2 years.

ABOUT THE PUMP

The rugged miniature diaphragm pump has electronically controlled timing function to operate only when sampling. It provides high flow rate and long operating life.
The pump is electronically timed to draw in the amount of sample required for the analysis, and then turns itself off after the pre-set sampling time (5 to 10 seconds).

OPTIONAL RECHARGEABLE BATTERY

If equipped with the optional battery, the 902D can within transported to your facility to conduct testing with no AC outlet available. Totally sealed, long-life battery (optional) accepts full or partial charging cycle. Charger module plugs into standard 115V outlet for charging or continuous operation, though it can accept 100-240V for worldwide use.


MICROPROCESSOR/ELECTRONICS

Micro-processor
based electronics provide sensor signal processing, battery charging,
pump timing and on/off control for high accuracy and reliability with
minimal component use and reduced size and cost.